MONO SODIUM GLUTAMATE powder and rods (3x 10 mm) were studied to be a radiation sensitive material for ESR dosimetry. Samples were irradiated with 60Co γ- rays. The developed signal after irradiation increases with the increase of the mono sodium glutamate in the rods. The prepared powder can be used in the dose range from (10-90) kGy, whereas the rods are useful in the range from (10-120) kGy. The obtained number of free radicals per 100ev (G value) was found to be 0.201± 0.01. The g factor is 2.0113± 0.0001. The rods have the advantage of negligible humidity effects during irradiation. The pre and post irradiation stability was found to be satisfactory.
(2014). ESR Dosimetric Properties of Sodium Glutamate. Egyptian Journal of Radiation Sciences and Applications, 27(1), 151-164. doi: 10.21608/ejrsa.2014.1515
MLA
. "ESR Dosimetric Properties of Sodium Glutamate", Egyptian Journal of Radiation Sciences and Applications, 27, 1, 2014, 151-164. doi: 10.21608/ejrsa.2014.1515
HARVARD
(2014). 'ESR Dosimetric Properties of Sodium Glutamate', Egyptian Journal of Radiation Sciences and Applications, 27(1), pp. 151-164. doi: 10.21608/ejrsa.2014.1515
VANCOUVER
ESR Dosimetric Properties of Sodium Glutamate. Egyptian Journal of Radiation Sciences and Applications, 2014; 27(1): 151-164. doi: 10.21608/ejrsa.2014.1515